Battery Storage Service

Dispatch, Ageing and Investment Analysis for Swiss Buildings

Operational
15min
Time Resolution
16
Published Sources
v0.1.0
API Version

API Endpoints

Data Sources

Swiss Methods & Market Data

Economic method: RAVEL (1992) — federal guide to the annuity and net present value methods for energy systems

Market study: BFE (2020) — interest rate, operating cost and end-of-life assumptions

Storage costs: Swissolar (2025) — Swiss battery price benchmarks

Electricity tariffs: ElCom — Swiss distribution network operator tariff data

Measurement & Modelling Standards

Self-consumption: Luthander et al. (2015) — peer-reviewed self-consumption and self-sufficiency definitions

Cycle counting: rainflow — ASTM E1049-85 rainflow counting on the state-of-charge trace

Efficiency: HTW Berlin (2024) — independently measured round-trip efficiency and standby draw

Measurement procedure: BVES Effizienzleitfaden 2.0 — efficiency and standby terms behind the HTW figures

Ageing: NREL BLAST-Lite — calendar ageing derived from its LFP cell models

Model Defaults

Round-trip efficiency: 87%
Usable depth of discharge: 90%
Cycle life: 6'000 full cycles to 80% capacity
Calendar fade: 0.6% per year at 25 °C
Storage cost: CHF 640/kWh + CHF 1'300 fixed
Calculation period: 15 years at 2.5% discount
Operating cost: 1% of the investment per year
Standby draw: 13 W

Every default is overridable per request. Every source is free to download. The full bibliography — 7 Swiss and 7 international sources, cited by page — is served at /api/v1/battery/references.

Data Disclaimer

Battery dispatch, ageing and economics are modelled from the PV and load time series supplied in the request, using published Swiss and international reference values. Actual storage performance and returns depend on the specific product, installation, tariff structure and usage pattern, and on future electricity prices. These calculations are for planning purposes only and are not investment advice.

Developed By

geoimpact AG

Project: Swiss Energy Planning (SEP)
Address: Schulhausweg 7, 4571 Lüterkofen
UID: CHE-370.148.023
Privacy: Datenschutz

Service Disclaimer

Die Inhalte des "Battery Storage Service" dienen ausschliesslich Informationszwecken und wurden mit grösstmöglicher Sorgfalt erstellt. geoimpact AG übernimmt jedoch keine Gewähr für die Richtigkeit und Aktualität der bereitgestellten Inhalte. Die Werte werden auf der Grundlage bestehender Datenquellen automatisiert berechnet.